For a home nas, a synology style linux software raid with regular data scrubbing is the peace of mind solution. If its a software raid, its possible that the boot loader cant load from that partition, because it doesnt have the raid software at bootup. Nov 09, 2015 what should happen in a raid setup is that the drives give up quickly. So you absolutely do want tlerercetc for a hardware raid setup. Minimum number of disks are allowed to create raid 0 is 2, but you can add more disk but the order should be twice as 2, 4, 6, 8. Aug 16, 2016 how to manage raid arrays with mdadm on ubuntu 16.
Here we are not using a hardware raid, this setup depends only on software raid. A raid can be deployed using both software and hardware. This howto does not treat any aspects of hardware raid. Tler is mostly important when you have a hardware raid controller. Now its raid 6, which protects against 2 drive failures. In computing, error recovery control erc is a feature of hard disks which allow a system. Western digital timelimited error recovery tler with. Get details of raid configuration linux stack overflow. Setup raid level 6 striping with double distributed parity in linux. We cover how to start, stop, or remove raid arrays, how to find information about both the raid device and the underlying storage components, and how to adjust the. I have four of the western digital caviar se16 500 gb wd5000aaks 16 mb sataii 300 mbs hard drive models.
The responses i received from synology, qnap, netgear, buffalo and highrely all indicated that their nas raid controllers dont depend on or even listen to tler, cctl, erc or. Hard drive question for linuxmdadm is erctler required. They just go for raid 5 or raid 6 and hope for the best. The advantage that software raid had in terms of speed have evaporated, leaving all block input fairly even across the board. For a quick summary of the problem, when the os tries to read from the disk, it sends the command and. Professional raid controllers use tler with tlerenabled disks to limit the time spend on. The os will handle timeouts just by waiting and be patient. I have a dell poweredge t105 at home and i am purcha the unix and linux forums. Wikipedia says raid 2 is the only standard raid level, other than some implementations of raid 6, which can automatically recover accurate data from singlebit corruption in data. We will be publishing a series of posts on configuring different levels of raid with its software implementation in linux. To setup raid 10, we need at least 4 number of disks.
This allows linux to use various firmware or driverbased raid volumes, also known as fake raid. References to ide and scsi have been deleted, all recent drives are sata. Using raid 6 on an array with less than 5 isnt recommended and on less than 4 is counterproductive. In a software raid configuration whether or not tler is helpful is dependent on the operating system.
If you want to use software raid with sata drives on an sc1425 server with suse linux, here is the procedure. They use mirroring, striping, or parity, and various combinations of these. Does anyone know if the raid 6 mdadm implementation in linux is one such implementation that can automatically detect and recover from singlebit data corruption. We have lvm also in linux to configure mirrored volumes but software raid recovery is much easier in disk failures compare to linux lvm. In a multiple drive software raid situation its a really bad thing. That determines if tlercctlerc is really necessary or not. Creating software raid0 stripe on two devices using. There are several different basic levels of raid, from raid 0 to raid 6. Linux software raid and drive timeouts the ongoing struggle. I expect that no data was written to the raid after it failed. Dec 22, 2011 linux software raid and zfs do not use tler and therefore are a safer choice for your data then regular hardware raid controllers.
The softwareraid howto linux documentation project. But the real question is whether you should use a hardware raid solution or a software raid solution. Tler isnt going to help with linux software raid unless you need to continuosly write to the drive surveillance. So you absolutely do want tler ercetc for a hardware raid setup. For the cache problem, a cheap ups that lasts the few minutes required to gracefully shut down is a good enough solution. For people really worried about tler cctlerc, you can run smartctl on your qnap and enable a 7 seconds timer yourself. It is not possible to boot an operating system from a software raid0 or raid5. Depends on whether the drives fire up reliably and timeout. But for linux software raid and zfs, you do not need tler. They had a good reputation in the linux world and i figured i. All that is relevant at the end of the day is what kind of timer if any the particular raid level uses, be it hardware raid or software raid. Taking a backup of the disks in the raid takes 24 hours, so i would prefer that the solution works the first time. The procedure can however be applied to other raid types as applicable. Software raid how to optimize software raid on linux.
Linux raid is different from windows for sound technical and. Most users who are familiar with linux software raid are also familiar with raidtools. Is hardware tlercctlerc in the hddnecessary on x39 models. It addresses a specific version of the software raid layer, namely the 0. We can use full disks, or we can use same sized partitions on different sized drives. Using raid6 on an array with less than 5 isnt recommended and on less than 4 is counterproductive. Software raid is one of the greatest feature in linux to protect the data from disk failure.
I have a dell poweredge t105 at home and i am purchasing the following. This howto describes how to use software raid under linux. That means for every bit written there are essentially two computations made, one for each parity. Here we will use both raid 0 and raid 1 to perform a raid 10 setup with minimum of 4 drives. If you have a different vendor install their tool if not yet present.
In testing both software and hardware raid performance i employed six 750gb samsung sata drives in three raid configurations 5, 6, and 10. Oraclebase configuring software raid on oracle linux 6. This article is a part 5 of a 9tutorial raid series, here we are going to see how we can create and setup software raid 6 or striping with double distributed parity in linux systems or servers using four 20gb disks named devsdb, devsdc, devsdd and devsde. Interestingly, the tler issue can be dealt with if you use the right controller firmware silicon image chipset or linux raid software any of the good nas products.
A raid array, no matter how many disks are in it, looks like a single logical storage drive to your system. Theoretically, there is no calculation done by the raid controller for the parity, etc. This article describes the steps required to configure software raid on oracle linux 6 ol6rhel6. Setup raid level 6 striping with double distributed. Jun 18, 2010 its really a feature designed to prevent long retries causing a hardware raid controller to chuck a disk out of a set whereas most nass use mdadm, which is a software raid controller, but even though the nas will not chuck a disk after a few seconds, the tler is still useful in that it will prevent a disk suffering an unrecoverable read.
Raid 0 was introduced by keeping only performance in mind. Zfs, and other software raid systems, will typically react the same way when tler is enabled, recovering data and remapping that block. If youre using software raid like linux mdraid, it probably doesnt matter. Jul 15, 2008 for the raid 6 performance tests i used 64kb, 256kb, and 1,024kb chunk sizes for both hardware and software raid. If you are going after high performance, you should be using ssds or hybrid drives, and make sure you match the performance of the drives to the performance of the bus. This article is a part 4 of a 9tutorial raid series, here we are going to see how we can create and setup software raid 6 or striping with. Nov 03, 2014 this article is a part 4 of a 9tutorial raid series, here we are going to see how we can create and setup software raid 6 or striping with double distributed parity in linux systems or servers using four 20gb disks named devsdb, devsdc, devsdd and devsdce. You can even move your array between any linux pc and mount it there and it will work great. Mdadm is linux based software that allows you to use the operating system to create and handle raid arrays with ssds or normal hdds. Sure enough, no enterprise storage vendor now recommends raid 5. This is the raid layer that is the standard in linux 2. The process is similar to that in ol5rhel5, but some of the screens look a little different. Raid 10 is a combine of raid 0 and raid 1 to form a raid 10. My take on it is that enabling tler, although not required, may make the system.
Setup raid level 6 striping with double distributed parity. This is the raid layer that is the standard in linux2. For what performance to expect, the linux raid wiki says about raid 5. I remember mfenn saying that they used lots of green drives in software raid setups and they were fine, ymmv. So which drives support scterctler and how much more do they cost. Linux uses either the mdraid or lvm for a software raid. Another level, linear has emerged, and especially raid level 0 is often combined with raid level 1. In the case of a failed read, raid just reads it from elsewhere and writes it back causing a sector reallocation in the drive.
That determines if tler cctlerc is really necessary or not. The tler question as you state isnt as relevant for raid 1 or 10. The monthly scrub that linux md does catches these bad sectors before you have a bad time. A software solution may be part of the operating system, part of the firmware and drivers supplied with a standard drive controller socalled hardwareassisted software raid, or it may reside entirely within the hardware raid controller. Replacing a failing raid 6 drive with mdadm enable sysadmin. Its extremely fast and supported by any linux distro on any hardware. If you have 2 x 500 gb hdd then total space become 1 tb. Linux software raid and zfs do not use tler and therefore are a safer choice for. Configure raid on loop devices and lvm over top of raid. Three years ago i warned that raid 5 would stop working in 2009. Assuming you had tler, after 7 seconds, it will instruct the raid adapter to not mark the drive bad and do it at a later time.
Linux file systems are generally fragile enough without throwing software raid and questionable hardware into the mix. Linux software raid benchmarking script louwrentius. So you need to make sure that the proper lvm tools package is installed. Im so much of a newbie that i cant even rent a clue as to the best distro for my intention. Western digital timelimited error recovery tler with raid.
It is used to improve disk io performance and reliability of your server or workstation. Software vs hardware raid nixcraft linux tips, hacks. A lot of software raids performance depends on the. A redundant array of inexpensive disks raid allows high levels of storage reliability. Is hardware tlercctlerc in the hddnecessary on x39.
Raid can be designed to provide increased data reliability or. Linux mdadm simply holds and lets the drive complete its recovery however, the default command timeout for the scsi disk. As the drive is not redundant, reporting segments as failed will only increase manual intervention. Which one is recommended for file server and database server. Just wanted to write up my experiences with my raid problems. The exception to the rule on software raid is xlv under xfs. However a desktop drive isnt suited to 247 operation and a 4tb drive will create a lot of vibration, heat etc which can all contribute to issues. You may still use such controllers but please test them properly but only to provide sata ports with individual disks, the raid part should be handled by linux. Raid redundant array of inexpensive disks or redundant array of independent disks is a data storage virtualization technology that combines multiple physical disk drive components into one or more logical units for the purposes of data redundancy, performance improvement, or both.
Essentially youre doing way too much work for no gain whatsoever. Linux software raid and zfs do not use tler and therefore are a safer choice for your data then regular hardware raid controllers. Not to mention the performance hit under heavy io not having a dedicated hardware controller handling all the striping and parity operations. Over the years, ive configured and happily used linux software raid on numerous servers. We just need to remember that the smallest of the hdds or partitions dictates the arrays capacity. Dont worry about tler, it doesnt affect software raid under linux. Moving from windoze hardware raid to linux software raid. Without a hardware raid controller or a software raid implementation to drop the disk, normal no tler recovery ability is most stable. Shown below is the graph for raid 6 using a 256kb chunk size. A redundant array of independent drives or disks, also known as redundant array of inexpensive drives or disks raid is an term for data storage schemes that divide andor replicate data among multiple hard drives. Jul 07, 2009 a redundant array of inexpensive disks raid allows high levels of storage reliability.
In this post we will be going through the steps to configure software raid level 0 on linux. Apr 28, 2017 how to create a software raid 5 on linux. It is absolutely true that this is a very important feature for hardware raid, because a hardware raid controller is probably configured to deem a hung hard drive as failed and to place it in an offline or recovery status, which has many negatives associated with it. Some people are confused and think that these features are only necessary for hardware raid, or arent useful for software raid.
As the name implies, this is a raid redundant array of inexpensive disks setup that is done completely in software instead of using a dedicated hardware card. However, there are certain limitations of a software raid. This allows linux to use various firmware or driverbased raid. Linux raid is different from windows for sound technical. In our earlier articles, weve seen how to setup a raid 0 and raid 1 with minimum 2 number of disks. I have seen some of the environments are configured with software raid and lvm volume groups are built using raid devices.
How to create a software raid 5 in linux mint ubuntu. Its really a feature designed to prevent long retries causing a hardware raid controller to chuck a disk out of a set whereas most nass use mdadm, which is a software raid controller, but even though the nas will not chuck a disk after a few seconds, the tler is still useful in that it will prevent a disk suffering an unrecoverable read. The distribution of data across multiple drives can be managed either by dedicated computer hardware or by software. I feel like ive been seeing a lot more threads on the linux raid mailing list recently where peoples arrays have broken, they need help putting them back together because they arent familiar with what to do in that situation, and it turns out that theres nothing much wrong with the devices in question other than device timeouts. Name your linux network interfaces like you would your children. My disks spent their time dropping on different builds even with tler disks only. Yes, we need more information about whats happening at bootup. Linux uses either the md raid or lvm for a software raid. The main advantage of such a thing is cost, as this dedicated card is an added premium to the base configuration of the system. But a couple years ago 2003 when i was building my newest server which conveniently lives in a collocation facility about 4 miles from where i do, i opted to drop in a 3ware card. Do not buy a hardware raid controller for home use louwrentius. You tend to boot from either a hardware raid, or a standard drive then use software raid for data. How to setup software raid for a simple file server on ubuntu. It can cause faster responsetimes when bad sectors do occur, however, so it may still have some use.
Many motherboards come with 6 sata connectors so setting up a. If you have a physical raid card with enough ports, you can add more disks. No hotswap is possible with software alone, without a hardware support. In general, software raid offers very good performance and is relatively easy to maintain. Depends on the size and chassis and how vital the setup is. I feel like ive been seeing a lot more threads on the linuxraid mailing list recently where peoples arrays have broken, they need help putting them back together because they arent familiar with what to do in that situation, and it turns out that theres nothing much wrong with the devices in question other than device timeouts. For people really worried about tlercctlerc, you can run smartctl on your qnap and enable a 7 seconds timer yourself. Configuring software raid on oracle linux 6 this article describes the steps required to configure software raid on oracle linux 6 ol6rhel6. It has proven to be amazingly resilient and quite stable. Set up software raid in rhel 6 migrate existing storage from nonraid to software raid resize raid volumes recover from a broken raid this document uses raid1 as an example while working with software raid. Hey, i have worked with linux for some time, but have not gotten into the specifics of hard drive tuning or software raid. This was in contrast to the previous concept of highly reliable mainframe disk drives referred to as single. Software vs hardware raid nixcraft nixcraft linux tips.
1571 844 866 379 721 451 77 1020 457 457 112 1209 265 559 796 806 447 359 265 355 1182 773 738 1379 416 76 1009 124 391